Phone: +886-2-23121582
Sale: sales@netpingdevice.com
Support: support@netpingdevice.com
NetPing east Co Ltd.
  • Monitoring units
    • UniPing server solution v4/SMS
    • UniPing server solution v3
    • NetPing IO v2

    • Overview

      UniPing v3

      Server room environmental monitoring solution by the Ethernet/Internet network. Allows to remotely get an information on a sensor status as well as notifications about a sensors operation. Support web, SNMP, HTTP API.

  • PDU
    • NetPing 8/PWR-220 v4/SMS
    • NetPing 2 IP PDU GSM3G 203R15
    • NetPing 2 IP PDU ETH 53R14

    • Overview

      NetPing 2/PWR-220 v3/ETH

      IP power distribution unit (IP PDU) for a remote management of power supply sockets via Ethernet/Internet network. Support web, SNMP, HTTP API.

  • POE devices
    • NP-SM4
    • Injector POE
    • Splitter POE
  • Sensors and accessories
  • Utilities and Software
  • Blog
    • Tutorial
    • FAQ
    • Press Releases
    • News
  • Home
  • Blogs
Government Standards for Location of Sensors in the Data Center
  • Created By : 25-Jun-2017
  • Published In: FAQ
  • Hits: 921

Government Standards for Location of Sensors in the Data Center


A location of humidity and temperature sensors is not regulated by the GOST (governmental standards).

The only recommendation about sensors occurs in CH512-78, and it is formulated the next way: "It is recommended to provide at least two temperature sensors that will allow to ensure an additional control over temperature conditions in a server room. One sensor is output to a console of a dispatcher of building engineering systems while the second sensor must be installed at the console of computer information network administrators.

Meanwhile, a proper location of temperature sensors is crucially important for a correct work of conditioning systems.

Read more
Controlling NetPing Devices Using a Mobile Phone
  • Created By : 02-May-2017
  • Published In: Tutorial
  • Hits: 371

Controlling NetPing Devices Using a Mobile Phone


SNMP (Simple Network Management Protocol) – is a standard Internet protocol for controlling devices in IP networks on the basis of TCP/UDP. architectures. Devices of remote control and monitoring NetPing sensors support the operation via SNMP protocol as well. One of convenient ways of monitoring is monitoring using a mobile phone.

In this article, an example of using "Monitor Master Free" software (free version) for remote controlling a NetPing device, namely controlling external devices (for example, a signal alarm or a light beacon) that are connected to IO lines in the "output" mode is described using UniPing server solution v4/SMS device, as well as controlling sockets of a NetPing 8/PWR-220 v4/SMS device as an example. 

Read more
NetPing Issued Firmware Update DKSF 70.6.6 DKSF 71.6.6 for UniPing server solution v4/SMS and UniPing server solution v3 Devices
  • Created By : 29-Jan-2017
  • Published In: Firmware Updates (Press Releases)
  • Hits: 383

NetPing Issued Firmware Update DKSF 70.6.6 DKSF 71.6.6 for UniPing server solution v4/SMS and UniPing server solution v3 Devices


NetPing east Co Ltd. announces the issue of firmware update for the devices for remote monitoring of server rooms UniPing server solution v4/SMS and UniPing server solution v3. New firmware versions for the devices contain implementation of new features and corrections of errors.

What have been changed in the latest version?

Read more
NetPing Issued Firmware Update DKSF 70.6.4 DKSF 71.6.4 for Devices UniPing server solution v4/SMS and UniPing server solution v3
  • Created By : 22-Nov-2016
  • Published In: Firmware Updates (Press Releases)
  • Hits: 367

NetPing Issued Firmware Update DKSF 70.6.4 DKSF 71.6.4 for Devices UniPing server solution v4/SMS and UniPing server solution v3


The company NetPing global Ltd. announces the issue of firmware updates for devices of remote monitoring of server rooms UniPing server solution v4/SMS and UniPing server solution v3. New firmware versions contain the implementation of new functionality and correction of errors.

What has been changed in the latest version?

Read more
NetPing Issued a Software Update DKSF 70.6.3 DKSF 71.6.3 for UniPing server solution v4/SMS and UniPing server solution v3 Devices
  • Created By : 09-Sep-2016
  • Published In: Firmware Updates (Press Releases)
  • Hits: 470

NetPing Issued a Software Update DKSF 70.6.3 DKSF 71.6.3 for UniPing server solution v4/SMS and UniPing server solution v3 Devices


NetPing east Co Ltd.company announces the issue of firmware updates for devices for remote monitoring of server rooms UniPing server solution v4/SMS and UniPing server solution v3. New firmware versions for devices contain implementation of new functionality, corrections of errors and a small design alteration of a device web interface.

What have been changed in the latest version?

Read more
How to Generate a Pulse on an IO Line When a Sensor of a Device Triggers?
  • Created By : 06-Jul-2016
  • Published In: FAQ
  • Hits: 678

How to Generate a Pulse on an IO Line When a Sensor of a Device Triggers?


NetPing devices have built-in IO lines (input-output lines). They can be used both in the «input» mode, and the «output» mode or a «logic output» for controlling external devices. Examples of using IO lines in the mode «output»/«logic output» are as follows:

  • remote rebooting of servers, which is an imitation of pushing a «Reset» button;
  • remote controlling of an alarm, lighting, a ventilator;
  • controlling electric lock, and electric gate at a remote site;
  • controlling the elements of a «smart home»: watering plants, opening / closing blinds, water pump, boiler, electric heaters, etc.;
  • remote controlling of an energy device (diesel generator, gasoline generator)
Read more
How to Organize Temperature Monitoring in a Server Room?
  • Created By : 27-Mar-2016
  • Published In: Tutorial
  • Hits: 473

How to Organize Temperature Monitoring in a Server Room?


Practical Use of Temperature Monitoring Devices

NetPing devices for temperature monitoring in a server room and implementation of other functionality use different modern techniques and protocols. The simplest method of watching temperature readings is using a built-in web interface. For example, at the page «Thermo sensors», it is possible to watch the readings of connected temperature sensors for a server room in a real-time mode:

Read more
Tracking Opening/Closing Doors Using NetPing and PRTG Network Monitor
  • Created By : 09-Mar-2016
  • Published In: Tutorial
  • Hits: 1022

Tracking Opening/Closing Doors Using NetPing and PRTG Network Monitor


One of the most important issues of a physical security of a server equipment as well as a security of the entire IT-infrastructure is tracking and controlling access to server rooms. A tracking system must notify system administrators and technical specialists about any access to a server room or protected object 24 hours a day 7 days a week with a possibility to browse a history of events in any moment of time. Such way of informing allows system administrators to control an access to the object without using expensive access control systems, which contain different types of electronic locks, components of employee identification via electronic maps, coded key locks and other security elements.

In this article, an example of organising the system of tracking access to server room on the basis of NetPing device and a monitoring system PRTG Network Monitor will be examined. The essence of the system is in monitoring a door opening/closing sensor, which is connected to a NetPing device by means of the PRTG monitoring system, as well as building a graph of opening a door within different time intervals.

Read more
NetPing Issued the Software Update DKSF 70.5.3 DKSF 71.5.3 for the devices UniPing server solution v4/SMS and UniPing server solution v3
  • Created By : 06-Mar-2016
  • Published In: Firmware Updates (Press Releases)
  • Hits: 535

NetPing Issued the Software Update DKSF 70.5.3 DKSF 71.5.3 for the devices UniPing server solution v4/SMS and UniPing server solution v3


NetPing company announces the issue of firmware updates for devices of remote monitoring of server rooms UniPing server solution v4/SMS and UniPing server solution v3. New firmware versions for devices contain error fixes and small implementations of new functionality.

What has been changed in the latest version?

Read more
Integrating NetPing Devices in Microsoft System Center Operations Manager (SCOM)
  • Created By : 03-Feb-2016
  • Published In: Tutorial
  • Hits: 723

Integrating NetPing Devices in Microsoft System Center Operations Manager (SCOM)


To control and monitor a corporate IT environment, it is possible to use the product from the Microsoft company named System Center Operations Manager (SCOM), which is included in the integrated management platform System Center. This product allows combining the information about the operability from different components of IT infrastructure, providing its generalized representation in one console. SCOM allows tracking services, devices and operations for many PCs in the network. Operators can rapidly estimate a state of IT environment and its IT services, run different systems and workloads using multiple representations, which show the information about a status, operability, and performance.

Read more
Example of Building Graphs for NetPing Devices in the Service Freeboard.io
  • Created By : 28-Jan-2016
  • Published In: Tutorial
  • Hits: 1071

Example of Building Graphs for NetPing Devices in the Service Freeboard.io


Previously, we examined an example of integrating NetPing devices with a cloud service dweet.io. A distinguishing feature of the service is a lack of the need to sign up or configure anything to work with it – data from your devices can be transmitted at once. You can watch changing data from sensors in the view of graphs via the address:

Read more
Example of Collecting Information from NetPing Devices in a Form of an Excel Table
  • Created By : 29-Dec-2015
  • Published In: Tutorial
  • Hits: 548

Example of Collecting Information from NetPing Devices in a Form of an Excel Table


On the basis of a developed functionality of sensor monitoring devices and remote controlling of NetPing power supply, it is possible to implement collecting information in different systems of monitoring and accounting. First of all, it is necessary to watch important parameters in the field of interest, as well as building various reports and charts for a specified period of time.

Receiving the information from NetPing devices can be flexible when based on the support of an SNMP protocol and specialized HTTP API commands. Everything necessary to do is to have a NetPing device with connected sensors, certain software or a script and a little time for configuring.

Read more
Example of NetPing Integration with the Service IoT dweet.io
  • Created By : 26-Nov-2015
  • Published In: Tutorial
  • Hits: 970

Example of NetPing Integration with the Service IoT dweet.io


In the previous publications on an integration of NetPing devices, two examples with cloud services of Internet of things concept (IoT) were examined: xively.com and thethings.io. Now it is a turn for the integration of NetPing devices with a similar service dweet.io to be examined.

A distinctive feature of this service is the fact that there is no need to sign up or configure something to work with it – data from your devices can be transferred at once. The service is built on the principle of objects named "things", into which a data is transferred through HTTP requests. In case if there is no object with such name, it is created automatically. A name for a future object must be unique.

Read more
How to Implement «Alarm Buttons» Using NetPing Devices?
  • Created By : 16-Nov-2015
  • Published In: FAQ
  • Hits: 708

How to Implement «Alarm Buttons» Using NetPing Devices?


NetPing devices for monitoring server rooms have one more remarkable feature – it will allow to organize a notification system on dangerous situations or emergencies at objects. Such systems are sometimes used at businesses for mass notification of staff or persons in charge, who must in turn take actions to evacuate people or eliminate adverse effects.

In this article an example of implementing «alarm buttons», i.e. a notification system, using NetPing devices will be regarded.

Three «alarm buttons» will be used in a notification system at the objects: №1, №2, №3. When clicking any of these buttons a siren alarm will trigger, which is installed at the object №4. In addition, there is one more button «Cancel» at the object №4, when clicking it a siren alarm is switched off.

Read more
Example of NetPing Devices Integration with the Service thethings.io
  • Created By : 15-Nov-2015
  • Published In: Tutorial
  • Hits: 501

Example of NetPing Devices Integration with the Service thethings.io


The service thethings.io offers a full range of solutions for the market of Internet of Things (hereinafter IoT) (Internet of things concept), as well as a simple and flexible API for the developers of IoT applications. This service is not related to any certain hardware platform and can be integrated with almost any device if it supports one of the next protocols: HTTP, Websockets, MQTT or CoAP. More detailed information on the issue can be learnt at this page of the project.

Read more
Example of Integrating NetPing Devices with a Service xively.com
  • Created By : 05-Nov-2015
  • Published In: Tutorial
  • Hits: 570

Example of Integrating NetPing Devices with a Service xively.com


As a majority of projects of the Internet of things concept (Internet of Things, IoT) or cloud services, the service xively.com:

  • Provides a platform (backend) for integration with other devices: a service is not connected to any certain hardware platform, instead it uses a standard HTTP API mechanism – this allows easy integrating of any device;
  • Can serve a platform for developing own applications: in the section for developers there are ready libraries for writing applications, including mobile ones, on different programming languages for different hardware platforms;
  • Offers a possibility for automation – triggers: a service allows interacting between different devices through the mechanism of HTTP POST requests
Read more
How to Use SMS Reports for NetPing?
  • Created By : 05-Nov-2015
  • Published In: Tutorial
  • Hits: 473

How to Use SMS Reports for NetPing?


Devices for remote monitoring of sensors via Ethernet network and remote controlling of power supply sockets with a built-in GSM modem have a feature of sending periodic SMS reports about a status of sensors and relays to service staff. These SMS reports allow to be constantly informed even of those monitoring objects that do not have a local data transfer network. Receiving the information on conditions of equipment operation, attempts to access the object or any other unplanned actions in time allows to avoid accidents at the object, thus eliminating equipment downtime and financial loss of business.

Read more
NetPing Issued an Update for DKSF 70.5.2 Firmware for the Device UniPing server solution v4/SMS
  • Created By : 13-Sep-2015
  • Published In: Firmware Updates (Press Releases)
  • Hits: 444

NetPing Issued an Update for DKSF 70.5.2 Firmware for the Device UniPing server solution v4/SMS


NetPing company announces issuing a new firmware update for a device for remote monitoring of server rooms UniPing server solution v4/SMS. This firmware version contains fixes of errors, introducing new functionality and updated layout of certain pages of a device web interface.

What has been changed in the latest versions?

Read more
How to Plug 1-wire Sensors to NetPing Devices
  • Created By : 17-Aug-2015
  • Published In: FAQ
  • Hits: 749

How to Plug 1-wire Sensors to NetPing Devices


Certain NetPing devices have got a possibility to work with 1-Wire sensors, such as 1-Wire temperature sensor, (THS), 1-Wire humidity sensor, (HS) and others. In turn, this allows to plug and configure sensors quickly and easily. After all, it is only to insert a cable with an RJ-11 plug into 1W (RJ-12) jack of the NetPing device to plug a 1-Wire sensor in.

In this article, we will examine plugging 1-Wire sensors to NetPing devices directly as well as using splitters and 1-Wire extenders.

Read more
How to Connect NetPing to TRASSIR
  • Created By : 14-Aug-2015
  • Published In: FAQ
  • Hits: 1089

How to Connect NetPing to TRASSIR


TRASSIR software, which is developed by the Russian company Digital Security Systems Lab (DSSL), is a leader in the area of developing professional software for digital video surveillance systems. A possibility to integrate monitoring devices of a server room and NetPing remote power supply monitoring devices is implemented in TRASSIR software. In this case NetPing devices serve as executing devices and allow to increase a functionality of the system TRASSIR, as well as expand the applicability of the devices NetPing in different automated systems and video surveillance complexes.

In this article, connecting NetPing devices to TRASSIR software will be examined.

Read more
  • |<
  • <
  • 1
  • 2
  • 3
  • >
  • >|

Blog Category

  • Tutorial
  • FAQ
  • Firmware Updates (Press Releases)
  • News
Featured
Integration of NetPing Devices into The openHAB Smart Home System
2021-01-30
Integration of NetPing Devices into The openHAB Smart Home System
NetPing setting up in OpenHAB is quite ordinary process since the device supports different management methods, including SNMP protocol. The...
Read more
Zabbix-email notifications: via NetPing with a built-in GSM modem
2020-10-11
Zabbix-email notifications: via NetPing with a built-in GSM modem
These universal monitoring systems as Zabbix are most often used to collect information from various devices. Zabbix notifications are confi...
Read more
Zabbix Templates for NetPing Server Room Environmental Monitoring Units and Power Distribution Units
2018-04-16
Zabbix Templates for NetPing Server Room Environmental Monitoring Units and Power Distribution Units
«... A template is a set of objects that may be applied to several nodes of the network.These objects may be:data elements;triggers;graphs;g...
Read more
Sequential Servers Startup with Pauses on the Basis of the New Module "Logic" of a NetPing Power Distribution Unit
2017-09-25
Sequential Servers Startup with Pauses on the Basis of the New Module "Logic" of a NetPing Power Distribution Unit
The logic module of the firmware of NetPing devices is designed for a simple automation and can perform such tasks as maintaining ...
Read more

 Facebook

Customer Service
  • How to Buy?
  • Contact Us
  • Support

Partners
  • Official Partners
  • How to Become a Partner?
Information
  • About Us
  • News
  • Tutorial
  • FAQ
  • Price List
Contact Us

We may offer ship our devices from our office to any place in the world!

  •  7F.-2, No.25, Sec. 1, Zhonghua Rd., Zhongzheng Dist., Taipei City 100, Taiwan (R.O.C.)
  •  Phone: +886-2-23121582
  •  Email: sales@netpingdevice.com
Newsletter

Subscribe to news, firmware, tutorial and FAQ on NetPing devices.

Copyright © NetPing east Co Ltd. All rights reserved.