- Monitoring units
- UniPing server solution v4/SMS
- UniPing server solution v3
- NetPing IO v2
Overview
UniPing v3
Server room environmental monitoring solution by the Ethernet/Internet network. Allows to remotely get an information on a sensor status as well as notifications about a sensors operation. Support web, SNMP, HTTP API.
- PDU
- NetPing 8/PWR-220 v4/SMS
- NetPing 2 IP PDU GSM3G 203R15
- NetPing 2 IP PDU ETH 53R14
Overview
NetPing 2/PWR-220 v3/ETH
IP power distribution unit (IP PDU) for a remote management of power supply sockets via Ethernet/Internet network. Support web, SNMP, HTTP API.
- POE devices
- Sensors and accessories
- Utilities and Software
- Blog
NetPing 1-wire hub, R912R2
27.00 USD
The Active Extender-Splitter for Connecting 1-wire Sensors to the NetPing Devices
|
NetPing Power Quality Monitoring Sensor 1-wire 910S21
36.00 USD
This sensor is designed to monitor the the quality of power in the outlet. The sensor must be connected to the RJ-12 (6P6C) connector of the NetPing device.
|
Temperature sensor 1-wire (THS)
19.00 USD
A temperature sensor -55°C ... +125°C with a 1-wire interface. A cable length is 2 meters. For NetPing server room environmental monitoring solutions and power distribution units.
|
Humidity sensor 1-wire (HS)
53.00 USD
A relative humidity sensor with a 1-wire interface and a built-in temperature sensor. For NetPing server room environmental monitoring solutions and power distribution units.
|
Temperature sensor T811
19.00 USD
A temperature sensor I²C for measuring an ambient air temperature indoors from -40°C to +125°C. Avoid water contacting a temperature sensor! For NetPing power distribution units.
|
Humidity sensor WS-2
51.00 USD
A relative humidity sensor for measuring relative humidity in % and a built-in temperature sensor. For NetPing power distribution units.
|
Smoke detector (mod. M206-5E)
22.00 USD
A smoke detector is designed to reveal a fire indoors, that is accompanied by a smoke. It can be plugged to NetPing server room environmental monitoring solutions.
|
NetPing Supply Voltage Sensor 995S2
18.00 USD
A sensor allows detecting the power voltage in the power outlet.
|
Door sensor metal
18.00 USD
A door position sensor. The sensor is designed to be mounted on a metal door of a cabinet or a server room. It contains reed contacts ("dry contact"). For NetPing server room environmental monitoring solutions and power distribution units.
|
Liquid sensor (mod.2605)
38.00 USD
A leakage sensor allows to define a presence of water in the spot where a sensor is installed. For NetPing server room environmental monitoring solutions and power distribution units.
|
PIR detector (mod.M105-1E)
26.00 USD
A motion sensor is designed to register movement. Allows to register any movement in a 10 meters area. It is connected to NetPing server room environmental monitoring solutions.
|
Airflow sensor + GRID 120 * 120 * 10mm NC
44.00 USD
The air flow sensor allows you to monitor the presence or absence of air pressure. It contains reed contacts ("dry contact"). It is connects to the IO line of a NetPing device.
|
Buzzer (mod.STD-3025)
29.00 USD
A siren alarm is designed to be plugged to NetPing server room environmental monitoring solutions. The siren allows to sound alert by a command from the interface of a NetPing device.
|
NetPing IRC-TR v2
51.00 USD
An IR module for devices remote control via TCP/IP network (web, SNMP, HTTP API) and SMS-commands with an IR interface (for example, remote control for air conditioner). It is not an independent device and it must be connected to a basic NetPing server room environmental monitoring solutions and power distribution units!
|
NetPing AC/DIN socket
28.00 USD
A controllable socket allows to turn on/turn off and restart power supply of 100V ... 240V AC, 50/60 Hz external load, with a current up to 10A. A socket has to be plugged into an IO line of a basic NetPing server room environmental monitoring solutions and power distribution units!
|
Adapter PWR-220
13.00 USD
An adapter for NetPing power distribution units (PDU). A special cable-adapter for connecting a euro plug from a computer socket to a usual power outlet in a body of a NetPing PDUs.
|
Adapter WA-320
9.00 USD
An universal adapter is designed to connect a power supply euro plug of a NetPing power distribution units (PDU) to a UPS socket (UPS, C13). In addition, an adapter can be used to plug a NetPing PDUs euro plug to a UPS socket (UPS, C13). A grounding contact of the adapter can be used with only a plug that has a pin as a grounding contact.
|
Power adapter 48V 1.5A
33.00 USD
A power adapter with an output voltage of 48V is designed to feed POE injectors, for example NP-SM4.
|
Cable extender 1-wire, 2m
5.00 USD
This is an extension cord for 1-wire sensors. It allows to lengthen a loop of a 1-wire sensor and plug 2 1-wire sensors to the same extension cord.
|
Cable extender 1-wire, 5m
12.00 USD
This is an extension cord for 1-wire sensors. It allows to lengthen a loop of a 1-wire sensor and plug 2 1-wire sensors to the same extension cord.
|
Cable extender 1-wire, 10m
15.00 USD
This is an extension cord for 1-wire sensors. It allows to lengthen a loop of a 1-wire sensor and plug 2 1-wire sensors to the same extension cord.
|
Cable 4 extender, 4m
8.00 USD
It allows to extend the length of a cord loop for 4 meters. Cable extender can be sequentially plugged in each other to achieve a necessary length of a sensor cord loop.
|
Power adapter 12V 0.5A
12.00 USD
This is a power adapter, which can be used to feed NetPing server room environmental monitoring solutions.
|