To buy
phone:+886-2-23121582
e-mail:sales@netpingdevice.com
Ask a question
phone:+886-2-23121582
e-mail:support@netpingdevice.com

38

ae5e2d4a-aa83-4113-8389-7dd9ba91439f

Liquid sensor (mod.2605)

water-sensor

http://www.netping.ru/Pub/Photos/_acces_sensr_water_sensr_small.png

38 usd
На складе 01.01 нет данных

Liquid sensor (mod.2605)

A leakage sensor allows to define a presence of water in the spot where a sensor is installed. 

  • It is mounted several millimeters above the floor in the place of possible water accumulation;
  • Output type "dry contact";
  • Power supply voltage of a sensor is 5V.
Описание

A leakage sensor allows to determine a presence of water in the place where a sensor is installed. A typical purpose of a leakage sensor is to alarm in case of a threat of flood in a room when a pipeline or a heating system is damaged, or when there is too much water from a condensing system of an air-conditioner.

Leakage sensors can be installed on the surface of floor or mounted straight into it and are fixed by silicone sealants. «Right» and properly mounted sensors will not be triggered by splashes and wet cleaning of the floor. Triggering is possible only when there is a serious flood and a water level is sufficient to circuit contact plates, which results in sending a signal from the sensor to a NetPing/Uniping device.

At the end of a sensor there are 2 metal plates. A sensor is triggered when a water film closes them. Usually a sensor is mounted a few millimeters above the floor in the place with inclination where water can accumulate.

Information about a sensor plugin is in the document "User Guide" for a device, to which you connect a sensor. Information about configuring a sensor and its functionality is in the document "Firmware Description" for a device, to which you connect a sensor.

A sensor is packaged with an inseparable cable, with connectors on the ends. A cable length can be increased with the help of flat cable extenders of RC-4 sensor, which are sequentially plugged one into another. Or it can be done independently with the help of any wire with a minimum cross section of 0,4 mm2. Maximum allowable length of a flat cable is 100 m.

Спецификация
Phisicals
Device dimenstions 65 x 14 x 18
Sensor cord length 2 m.
Weight 55 g.
Device suit Sensor, package
Документация и файлы
Подключаемые устройства

9

31fdb1f1-30f6-4748-9cd6-2e7bc5df11fe

Cable 4 extender, 4m

rc-extender-4m

http://www.netping.ru/Pub/Photos/_acces_mains_sensors_extender4_small.png

Cable 4 extender, 4m
9 usd

44

4959ec53-f517-4763-b464-b58f1fa3999f

NetPing IO v2

netping-io-v2

http://www.netping.ru/Pub/Photos/_nping_bases_v2netpingIO_small.png

NetPing IO v2
44 usd

180

bf267fd2-62fc-4fa3-8263-41529299273d

UniPing server solution v3

uniping-server-solution-v3

http://www.netping.ru/Pub/Photos/_nping_bases_UniPing_server_v3_small.png

UniPing server solution v3
180 usd

247

02b17980-856c-4c63-aa13-de9a7127678c

UniPing server solution v3/SMS

uniping-server-solution-v3-sms

http://www.netping.ru/Pub/Photos/_nping_bases_UniPing_server_v3_SMS_small.png

UniPing server solution v3/SMS
247 usd

120

063dab6d-cdc8-4fe7-a6b3-61dde5aa4841

NetPing 2/PWR-220 v1/SMS

netping-2-pwr-220-v1-sms

http://www.netping.ru/Pub/Photos/_nping_power_SMS2PWR220-v1_small.png

NetPing 2/PWR-220 v1/SMS
120 usd

84

88f0327b-0d9e-4206-b59d-5ad21fb0b466

NetPing 2/PWR-220 v3/ETH

netping-2-pwr-220-v3-eth

http://www.netping.ru/Pub/Photos/_nping_power_ETH_2PWR220_v2_small.png

NetPing 2/PWR-220 v3/ETH
84 usd

305

882486d3-2060-4810-a709-8638ed917d9b

NetPing 8/PWR-220 v3/SMS

netping-8-pwr-220-v3-sms

http://www.netping.ru/Pub/Photos/_nping_power_8PWR_SMS_small.png

NetPing 8/PWR-220 v3/SMS
305 usd

135

af100b29-4903-4965-885f-162bb8caf43d

NetPing 2/PWR-220 v2/SMS

netping-2-pwr-220-v2-sms

http://www.netping.ru/Pub/Photos/_nping_power_v2SMS2PWR220_small2.png

NetPing 2/PWR-220 v2/SMS
135 usd

-+ usd usd
Subtotal usd

Your Order